7 matches found
CVE-2021-45117
CVE-2021-45117 concerns the OPC UA ANSI C stack stubs in the NodeSets. The root cause is a NULL pointer dereference caused by not handling all error cases in generated code, potentially crashing an OPC UA client (and possibly a server in certain usage). The vulnerability is reported with a CVSSv3...
CVE-2018-4832
CVE-2018-4832 affects Siemens SPPA-T3000 and related OpenPCS/WinCC/BATCH/Route Control components. The vulnerability stems from improper input validation in the RPC service, enabling a remote attacker with network access to cause a DoS in remote and local communication, requiring a reboot to rest...
CVE-2019-10929
CVE-2019-10929 affects Siemens SIMATIC products (S7-1200/1500 families, ET200SP Open Controllers, HMI/WinCC/STEP 7, TIM 1531 IRC, etc.). The flaw is a message protection bypass caused by properties in the integrity-protection calculation, enabling a man-in-the-middle attacker with network access ...
CVE-2020-7580
CVE-2020-7580 affects Siemens products (e.g., SIMATIC Automation Tool, STEP 7/TIA Portal, WinCC OA, ProSave, S7-1500 controllers, etc.). Root cause: a common component calls a helper binary with SYSTEM privileges while the call path is not quoted (unquoted search path/element CWE-428). This could...
CVE-2021-40142
In the OPC Foundation Local Discovery Server (LDS), versions before 1.04.402.463 are vulnerable to a DoS caused by crafted messages that trigger an access to memory location after the end of a buffer (CVE-2021-40142). The issue affects LDS and related Siemens products listed in ICS/CISA advisorie...
CVE-2021-40359
CVE-2021-40359 is a path traversal vulnerability in Siemens products (OpenPCS 7, SIMATIC BATCH, SIMATIC NET PC Software, SIMATIC PCS 7, SIMATIC Route Control, SIMATIC WinCC, etc.). The issue arises from improper neutralization of special elements in pathnames when downloading files, allowing an a...
CVE-2019-19282
CVE-2019-19282 describes an incorrect calculation of buffer size (CWE-131) that allows a remote attacker to cause a denial-of-service on Siemens industrial software when encrypted communication is enabled. Exploitation requires network access and no privileges/UI. Affected products span OpenPCS 7...